PRODUCT RANGE · 70 models · 72 versions
Distribution manifolds
Distribute air through your planned ventilation branches. We’ll help check manifold connections and compatibility with the ducts and terminals.
Ask us about availability, configuration and installation.
Models & specifications
Choose a model/version to view its dimensions, ratings and supply details.
Check the dimensions and electrical supply for the version you choose. We can help you confirm the right fit.
01Universal manifold
+
In galvanized sheet metal, insulated on all sides. Interchangeable air inlet and inspection door. Pre-punched closed outlets to be opened on site according to the desired connection configuration. Supply including: 4x wall anchoring brackets sliding along external guides on the manifold body for installation at the correct height, 1x inlet reducer.
02Universal manifold 4X DN 125 mm. 4x DN 75/90 mm straight front / 4x DN 75/90 mm perpendicular on the left side. / 4x DN 75/90 mm perpendicular to the right side. / 4x 75/90 mm perpendicular above
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals03Universal manifold 8X DN 160 mm. 8x DN 75/90 mm straight front / 4x DN 75/90 mm perpendicular on the left side. / 4x DN 75/90 mm perpendicular to the right side. / 8x 75/90 mm perpendicular above
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals04Universal manifold 12X DN 160 mm. 12x DN 75/90 mm straight front / 4x DN 75/90 mm perpendicular on the left side. / 4x DN 75/90 mm perpendicular to the right side. / 12x 75/90 mm perpendicular above
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals05Universal manifold 15X DN 250 mm. 15x DN 75/90 mm straight front / 4x DN 75/90 mm perpendicular on the left side. / 4x DN 75/90 mm perpendicular to the right side. / 15x 75/90 mm perpendicular above
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals06Corrugated tube start
+
Male / female adapter for direct connection between manifold for round tubes and round tubes themselves. Equipped with internal end-of-stroke shapes for correct engagement and hooking.
07Corrugated pipe outlet / DN 75 mm. Attack: M/F
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals08Corrugated pipe outlet / DN 90 mm. Attack: M/F
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals09Dynamic flow regulator
+
Dynamic constant flow limiter with self-adjusting variable inclination internal element. For direct installation inside the manifold / plenum outlets. Maintains the flow rate set by the front selector regardless of the position in the system and without the aid of external energy.
10Dynamic flow regulator in PE / DN 80 mm. Operating range: 15-50m³/ h (step 5 m³/ h)
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals11Dynamic flow regulator in PE / DN 125 mm. Operating range: 100-180 m³/ h
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals12Dynamic flow regulator in PE / DN 125 mm. Operating range: 50-100 m³/ h
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals13Static flow regulator
+
Static constant flow limiter with concentric internal elements. For direct installation inside the manifold / plenum outlets. Depending on the number of concentric discs that are removed, the passage section increases.
14Static flow regulator in PE / DN 80 mm / Connection: M. Pack of 12 pcs., Price in € / pcs.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals15Anti-static and antibacterial round corrugated tube
+
Highly flexible, double layer corrugated externally and smooth internally. Antiseptic and antibacterial treatment of the internal surface to ensure easy cleaning and high flow rates. For installation in caldana, in false ceilings or on walls. Operating temperature: -25 / + 60 ° C. Compressive strength according to EN ISO 9969:> 8 kN / m.
16Antistatic and antibacterial corrugated hose / DN 75 mm / Bend radius: min 150 mm. Supplied in 50m spools, price in € / m
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals17Antistatic and antibacterial corrugated hose / DN 90 mm / Bend radius: min 150 mm. Supplied in 50m spools, price in € / m
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals18Sleeve
+
Female / female sleeve for coupling sections to round tubes. The internal end-stroke shapes prevent the tubes from being inserted too deeply. Additional external clips ensure a mechanical closure of the connection.
19Sleeve for corrugated pipes in HDPE / DN 75 mm. Attack: F / F
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals20Sleeve for corrugated pipes in HDPE / DN 90 mm. Attack: F/F
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals21O-Ring
+
Ring seal for round tube. Thanks to the properties of the special construction material, no lubricants are required.
22Sealing O-ring in EPDM / DN 75 mm. Pack of 10 pcs., Price in € / pcs.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals23Sealing O-ring in EPDM / DN 90 mm. Pack of 10 pcs., Price in € / pcs.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals24Plug
+
Blind sealing cap for hygienic protection of the interior of round tube systems.
25Blind plug in PE / DN 75 mm. Pack of 5 pz., Price in € / pz.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals26Blind plug in PE / DN 90 mm. Pack of 5 pz., Price in € / pz.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals27Clip
+
Fixing clip for round corrugated pipes with simple coupling in plastic material.
28PE / DN 75 mm fixing clip. Pack of 12 pcs., Price in € / pcs.
+Version 28
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals29PE / DN 75 mm fixing clip. Pack of 12 pcs., Price in € / pcs.
+Version 29
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals30Insulating sheath for corrugated pipes
+
Insulating sheath in polyethylene produced by continuous extrusion and expansion. External protective coating. Color: Grey.
31PEE insulating sheath / DN 75 mm / Operating temperature: +8/90 ° C / Degree of insulation: 0.038 W / mK / Bending radius: min 150 mm. Supplied in 15 m reels, price in € / m
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals32PEE insulating sheath / DN 90 mm / Operating temperature: +8/90 ° C / Degree of insulation: 0,038 W/mK / Bending radius: min 150 mm. Supplied in 15 m reels, price in € / m
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals3390° corner for corrugated pipes
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals3490° corner for corrugated pipes. DN 75 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals3590° corner for corrugated pipes. DN 90 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals36Insulated steel manifold
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals37TG2 insulated steel manifold with inspection door and outlets at the front. 1x DN160 mm - 3 x DN 125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals38TG3 insulated steel manifold with inspection door and front outlets. 1x DN160 mm - 5 x DN125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals39TG2 insulated steel manifold with inspection door and front outlets. 1x DN200 mm - 5 x DN125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals40TG3 insulated steel manifold with inspection door and front outlets. 1x DN200 mm - 5 x DN125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals41TG4 insulated steel manifold with inspection door and front outlets. 1x DN250 mm - 6 x DN125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals42Steel plenum box
+
Guide channels for laying flush with the wall on 4 sides. Opening of the same on the 2 opposite sides for sliding grids with magnetic attachment. Supply including: 4x wall anchoring brackets sliding along external guides on the plenum body for installation at the correct depth, 2x reducer for magnetic attachment grids.
43Plenum vent in galvanized sheet. Dimensions 300x200 mm. 1xDN125 hose connection: universal on all sides
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals44Plenum vent in galvanized sheet. Dimensions 400x150 mm. 1xDN125 hose connection: universal on all sides
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals45Universal insulated EPP plenum for one box system
+
Contains 1x One box diffuser. 4 end caps, 2x pipe adapters DN 75/90 mm, 1x connection coupling for multiple configuration, 2x brackets, 2x screws. Hygienic material with flat inner surface and conductivity λ=0.042 W/mK. Selection of adapter diameter and positioning, open outlets to be closed on site. The adapter can be installed depending on the arrival of the pipe on the 5 sides of the diffuser.
46Universal vent / single plenum kit for multiple configurations, several single plenum boxes can be combined in different combinations; 1x single, 2x dual, 3x triple, 4x quadruple. To be combined with perforated grille / 1+1+1+1 DN 75/90 mm / Dimensions: 1
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals47Kit plenum universale in ABS
+
Kit plenum universale in ABS con manicotti in polipropilene che prevedono il collegamento del tubo corrugato. Possibilità di regolazione della portata tramite apposite serrande inseribili all'interno dei manicotti.
48Diffusore in ABS con 4 tappi, 1 ingresso tubo DN 75 mm con serranda staffe di installazione e coperchio.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals49Manicotti opzionali
+Version 49
Manicotti aggiuntivi con serranda di regolazione.
50Manicotto DN 75 mm con serranda per sistema Slim Box.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals51Manicotti opzionali
+Version 51
Manicotti aggiuntivi con serranda di regolazione.
52Manicotto DN 90 mm con serranda per sistema Slim Box.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals53Filtro
+
Filtro di ricambio Coarse per sistema Slim Box.
54Confezione 10 pezzi
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals55Kit isolamento termico
+
Kit isolamento per plenum Slim Box
56Kit isolamento per plenum Slim Box composto da polietilene adesivo fustellato a dimensioni per incollaggio rapido.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals57Plenum rigido da controsoffitto H variabile
+
Adattatore 2 tubi
58Adattatore 2 tubi diametro 75 mm - per griglia diametro 125 mm. Dimensioni (lxhxp): 205x380x200 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals59Adattatore 2 tubi diametro 90 mm - per griglia diametro 125 mm. Dimensioni (lxhxp): 210x400x200 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals60Griglie per sistema controsoffitto
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals61Griglia quadrata con deflettori, diametro attacco 125 mm.
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals62Griglie in ABS
+
Griglie in ABS bianca per mandata e ripresa
63Diametro attacco 125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals64Steel plenum for flex system
+
Guide tracks for installation flush with the wall on 4 sides. Opening of the same on 2 opposing sides for magnetic grid slide. Including supply of: 4x wall mounting brackets sliding along external guides on plenum box body for installation at the correct depth, 2x reducer for magnetic grids.
6590° corner plenum box in galvanised sheet metal for hoses / 1xDN125 mm / Dimensions: 300x200 mm. Connection: M
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals6690° corner plenum box in galvanised sheet metal for hoses / 1xDN125 mm / Dimensions: 400x150 mm. Connection: M
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals67Extension for circular plenum box
+
Extension for circular plenum box for ceiling installation
68Circular plenum box extension for ceiling/wall installation made of HDPE, L = 100 mm. Multiple connections possible. Ø 125 mm to Ø 125 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals69Delivery grid
+
Aluminum delivery grille with double row of adjustable fins, white color.
70Dimensions: 450x225 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manuals71Suction grid
+
Suction grid with removable aluminum filter, white color.
72Dimensions 450x 225 mm
+
Check the documents below for this product’s configurations and installation requirements. If you need a particular specification, ask us to help you confirm it.
View specifications and manualsNo model matches. Try a shorter model number.
Brochures and manuals
View the full product details, or ask our team to help you choose.
View specificationsCheck this model for your space
Tell us about your space and the model you are considering. Our AC & HVAC team will help check the fit, confirm availability and plan installation and ongoing care.
What to send us
- Room use and dimensions
- Model and configuration
- Existing system or available connections
- Installation and service access
- Supply, installation and aftercare needs